Automatic Transfer Switch Changeover Switch 100A to 630A ATS

Product Details
Customization: Available
Warranty: 1 Year
Operation: Electric
Still deciding? Get samples of US$ 20/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10000000 RMB
Plant Area
501~1000 square meters
  • Automatic Transfer Switch Changeover Switch 100A to 630A ATS
  • Automatic Transfer Switch Changeover Switch 100A to 630A ATS
  • Automatic Transfer Switch Changeover Switch 100A to 630A ATS
  • Automatic Transfer Switch Changeover Switch 100A to 630A ATS
  • Automatic Transfer Switch Changeover Switch 100A to 630A ATS
  • Automatic Transfer Switch Changeover Switch 100A to 630A ATS
Find Similar Products

Basic Info.

Type
Integrated automatic transfer switch
Poles
4P
Product Name
Automatic Transfer Switch
Rated Voltage
230/400V
OEM
Yes
Current
100A,160A,250A,400A,630A
Transport Package
Carton Packing
Trademark
GWIEC
Origin
China Zhejiang
Production Capacity
200PCS/Monthly

Product Description

Products introduction:


This product is PC-class automatic transfer switch/It is mainly used for AC 50/60HZ,rated voltage of 400V and below,and rated working current of 1250A in a two-neutral grounded power supply system.Switch between them to ensure the reliablity and safety of power supply.
The ATS has 'normally closed','backup closed'and 'two-way open' positions.It is widely used in automatic  conversion of common power supply and backup power supply of power supply system or automatic conversion and safety isolation of two load devices.
The product is compliant with the standard of GB/T14048.11 'low voltage switchgear and control equipment-part 6-1:Multifunctional electrical transfer switch electrical appliances'. 
Working conditions:
1.Ambient temperature:The ambient temperature is -5ºC-+40ºC,and the average temperature should not exceed +35ºC within 24 hours.
2.Atmospheric humidity:When the maxium temperature is +40ºC,the relative humidity should not exceed 50%,and the monthly maxium relative humidity is 90%.Higher relative humidity can be allowed at lower temperature.Spercial measures should be taken for the occasional condensation caused by temperature changes.
3.Installation height:The altitude of the installation site should not exceed 2000 meters.
4.Pollution level:The environmental pollution level of the installation site is level 3
5.Usage category:The use category is :AC-33B
6.Electromagnetic environment:Acclicable to environment A.The use of this product in environment B will cause harmful electromagnetic interference,in which cause the user needs to take appropriate protective measures.
Technical parameters:
Function paramter sheet

Item Type A Type C Type D
Working power AC 230V 50/60Hz
Auxilary working voltage AC230V
Power consumption ≤10W
Working positions Three working positions
Operation Automatic,manual and manual remote control operation
Working mode automatic switching and automatic recovery/automatic switching without automtic recovery
Display Only the power supply and closing signal LED display integrated single-phase detection
Installation All-in-one
Voltage monitoring Single phase detection Single phase detection Three-phase phase loss detection
Generator control /
Fire-fighting linkage control / √(Passive contact input)


Technical parameter sheet
 

Frame current(A) 100 160 250 400 630 1000 1250
Rated insulation voltage 690V
Rated impulse withstand voltage 8KV
Rated working current(A) 16a,20A,25A,30A,40A,
50A,60A,63A,70A,
75A,80A,100A
125a 140A 160A 200A 225A 250A 315A 350A 400A 500A 630A 800A 1000A 1250A
Rated short-circuit making capacity 8KA 17KA 26KA 50KA
Rated limited short-circuit current 120KA
Control voltage AC230V


Product functions:

Controller code Feature
Type A 1.Common power indication and closing status indication
2.Backup power indication and closing status indication
3.Single-phase(A-phase)phase loss detection
Type C 1.Common power indication and closing status indication
2.Backup power indication and closing status indication
3.Single-phase(A-phase)phase loss detection
4.Fire-fighting linkage,power generation start and stop function
Type D 1.Common power indication and closing status indication
2.Backup power indication and closing status indication
3.Fire protection linkage,power generation start and stop function,three-phase phase loss detection
Automatic Transfer Switch Changeover Switch 100A to 630A ATSAutomatic Transfer Switch Changeover Switch 100A to 630A ATSAutomatic Transfer Switch Changeover Switch 100A to 630A ATSAutomatic Transfer Switch Changeover Switch 100A to 630A ATS
Automatic Transfer Switch Changeover Switch 100A to 630A ATSAutomatic Transfer Switch Changeover Switch 100A to 630A ATSAutomatic Transfer Switch Changeover Switch 100A to 630A ATS

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.