Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter

Yueqing Greenwich Imp & Exp Co., Ltd.
  • Audited Supplier
  • 10 yrs

Contact Supplier

Product Highlights

  • Versatile Starting Modes: Offers 5 modes including ramp voltage, current limit, and snap action for various load conditions.
  • Comprehensive Protection: Features 7 protection types including over-voltage, phase loss, short circuit, and thermal overload.
  • Wide Voltage Compatibility: Supports input voltages from 220V to 660V at 50/60Hz for global power grid compatibility.
  • Advanced Control Functions: Includes start delay, running delay, auto-restart (up to 9 times), and error message storage.
  • Multi-Level Production Settings: Five adjustable levels from elementary to advanced to optimize performance for specific applications.
  • Pump and Fan Optimization: Reduces hydraulic shocks, mechanical stress, and starting current for pumps and fans.
  • Real-time Monitoring: Provides 4-20mA DC analog output and multi-display for voltage, current, and thermal status.

Product Images of Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter

Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter
Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter pictures & photos
Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter
Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter pictures & photos
Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter
Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter pictures & photos
Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter
Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter pictures & photos
Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter
  • Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter
  • Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter
    Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter
  • Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter
    Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter
  • Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter
    Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter
  • Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter
    Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter

Find Similar Products

Product Description

Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter 

Introduce

Soft starter are a far better alternative to star/delta and auto transformer starters.
The star/delta starter reduces start current but introduces a damaging torque transient when switching from star to delta connection. Furthermore star/delta starting does not always selection of the best start current level.
This sometimes means the load cannot accelerate to full speed in star configuration thereby making the star/delta
starter totally in effective.

A star/delta starter does not impact the way the motor stops, thus leaving the voltage ramp down with no control. The auto transformer reduces start current but also allows some control over the level of start current. Auto transformer starters does not eliminate the risk of a jump in torque when shifting voltage.

 

Working Condition

1. Power grid, self-provided power plant, electric generator : three phase 380V or 660V (specifical designed)  ±15%, 50Hz or 60Hz, power capacity have to meet soft starter and motor starting requirement

2. Suitable motor: Squirrel cage three-phase asynchronous motor and the motor reated power shall be match with soft starter power 

3. Starting time frequency: no special requirement, depends on the situation

4. Cooling method: Natural air cooling

5. Protection: IP20

6. Environment condition: altitude under 1000meters, temperature: 0 ~ 40 degree Celsius, humidity:  under 90% RH

 

Pump 

1. Reduce hydraulic shocks in pipelines during start and stop.
2. Minimize mechanical stress on motor shaft.
3. Reduce starting current .
4. Under-current protection preventing damage from blocked pipe or low water situations.
5. Automatic reset functionality ensures continued operation of unmanned pump stations.
6. Phase rotation protection prevents damage from reverse pump rotation.
7. Instantaneous overload protection prevents damage from debris drawn into the pump.

 

Fans

1. Smooth application of torque preventing mechanical stress.
2. Reduced starting times over star/delta starting.

Power Supply: City power, Electricity Generator, Input three phase AC 220/380V/440/660V, 50/60Hz, Battery capacity should comply soft starter boot require.

Suitable For : Three phase squirrel cage induction motor, rated frequency should be match with soft starter
Starting Frequency: No Specific Requirement

Cooling : Natural air cooling
Protect Level : IP 20
Environment : Altitude of 3000 meters below;
Ambient temperature: -25~+40ºC;
Relative humidity : <90%;
Non-condensing, non-flammable, corrosive gases;
Non-conductive dust, good ventilation, low-vibration.

 

Protection

1. Voltage loss, undervoltage, overvoltage 

2. Over-Current while starting or running

3. Soft starter over heat

4. Starting over time 

5. Input or output phase losses

6. Three phase unbalance 

7. Short circuit

 

5 Mode of Start
Ramp voltage start :Require a smooth start occasion, output voltage as Page 1.
Current limit start : Have strict limitation of starting current, motor current curve as Page 2.
Snap action + Ramp voltage start : For heavy load, static friction force too big cause motor not running, starting curve as 
Snap action + Current limit start : For heavy load, static friction force too big cause motor not running, starting curve as 
Heavy load strong shock start : For difficulty of heavy load motor start

 

5 Level Production Setting:
For different occasions, JJR2 production divide into five level, 0=Elementary ; 1: light load ; 2 : Standard 3 : Heavy load 4 : Advanced, Set by F12 Elementary forbid connect Instantaneous stop function, only have over-heat,
short circuit and default phase protection, suitable for Unconditional emergency start, like fir pump.
Light-load / Standard / Heavy-load has most of protection function, only difference is motor over load heat protection time curve as Page 1 & 5Advance as starting protection is more strict, parameters is like Heavy-load

 

Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter

 

10 Optional Functions
Start delay : 0 ~ 999s, shows as timer, start when it goes "0"
Running delay output : 0 ~ 999s, From received the signal, delay output closing contact
Starting interval delay : 0 ~ 999s, Light flash in this period, time's over allow restart
Over-heat unlock delay : 0 ~999s, after over heat happen and release
Error message storage: Last 9 error message
Auto restart : set for 9 times of auto start, used long-term continuous operation & Unattended occasions
0-20A DC analog output : real-time motor current indicator, max-load 300 Ω
Multiply display: Able to indicator power voltage, motor current, apparent power, thermal equilibrium,etc.

Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter
Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft StarterTriple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter


Triple 11 Kw 15 30 Start Motor Controller Single Phase Soft StarterTriple 11 Kw 15 30 Start Motor Controller Single Phase Soft StarterTriple 11 Kw 15 30 Start Motor Controller Single Phase Soft StarterTriple 11 Kw 15 30 Start Motor Controller Single Phase Soft Starter

 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR2231514". Items marked "verified" are certified.

Watch Video
Watch Video
Yueqing Greenwich Imp & Exp Co., Ltd.
Yueqing Greenwich Imp & Exp Co., Ltd.
Yueqing Greenwich Imp & Exp Co., Ltd.
Yueqing Greenwich Imp & Exp Co., Ltd.
Yueqing Greenwich Imp & Exp Co., Ltd.
Yueqing Greenwich Imp & Exp Co., Ltd.
Yueqing Greenwich Imp & Exp Co., Ltd.
Yueqing Greenwich Imp & Exp Co., Ltd.

About Our Factory & Business Background

Address
The First Industrial Zone, Qiligang, Zhejiang, China
Terms of Payment
LC, T/T, PayPal
International Commercial Terms(Incoterms)
FOB
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: one month
Nearest Port
ningbo

Our Production Capability & Technical Expertise

Main Products
MCCB, Contactor, Starter, Connector, Relay, Magnetic Starter, MCB, Circuit Breaker, DC Contactor, Vacuum Breaker

Our Industry Experience & Global Business Record

Export Year
2017-07-19
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What are the available starting modes?
The soft starter supports five modes: Ramp voltage start, Current limit start, Snap action + Ramp voltage start, Snap action + Current limit start, and Heavy load strong shock start.
What protection features does the soft starter include?
It includes protection against voltage loss, undervoltage, overvoltage, over-current, overheating, starting over time, phase losses, three-phase unbalance, and short circuits.
Can the soft starter be used for pump applications?
Yes, it reduces hydraulic shocks, minimizes mechanical stress on the motor shaft, and includes under-current and phase rotation protection for pump stations.
What are the optional functions available?
Optional functions include start delay, running delay, starting interval delay, over-heat unlock delay, error message storage, auto-restart, and 4-20mA DC analog output.
Is the soft starter suitable for heavy loads?
Yes, it features specific modes like Snap action + Current limit start and Heavy load strong shock start designed for motors with high static friction.
What is the cooling method used?
The soft starter uses natural air cooling and requires good ventilation with low vibration.
How many times can the auto-restart function operate?
The auto-restart function can be set for up to 9 times of auto-start, suitable for long-term continuous operation and unattended occasions.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now