Electricity Type: AC
Number of Pole: 2
Phase: 1
Main Circuit Rating Voltage: 380V
Main Circuit Rating Current: 100A
Type: Ac Contactors
Samples:
US$ 2/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
CJX9
Transport Package
Export Standard Packing
Trademark
GWIEC or OEM
Origin
Zhejiang

Product Description

GWIEC Hight Quality AC Definite Purpose Contactor

Product Description
 
  • 2 Year Replacement Policy
  • 40 FLA Amp Rating - 2 Pole - 24 Volt Coil. Replaces Most 2 Pole Contactors Rated at 20 Amps, 25 Amps, 30 Amps, 35 Amps, or 40 Amps on Air Conditioners and Heat Pumps
  • Enclosed Contacts and Encapsulated 24 Volt Coil
  • Heavy Lug Terminals and Push-Ons for High Voltage Connections
  • Contactor for HVAC, Motor, Heating & Refrigeration- Replaces Carrier - Bryant - Payne, Goodman, Amana, Janitrol, Rheem, Ruud, Weatherking, Lennox, Trane, American Standard and Many Others

Definite Purpose Contactor Application:

  • CJX9 (Or HX20) Series Air Condition AC Contactor is mainly applicable to a line of AC 50Hz or 60Hz, rated insulation voltage is 240V and rated working current up to 60A, used to close or switch off the line
  • Air conditioner contactors are definite purpose AC contactor are designed for use in refrigeration, air conditioning, and electric heating systens.
  • Power connections can be made with either screw terminals with quick connects or lug terminals with  quick connects
  • They comply with IEC60947-4-1
  • Gwiec 2 Pole 40 AMP Heavy Duty AC Contactor Replaces Virtually All Residential 2 Pole Models (2- Year Warranty-High Quality Silver Alloy Content Contactors)Gwiec 2 Pole 40 AMP Heavy Duty AC Contactor Replaces Virtually All Residential 2 Pole Models (2- Year Warranty-High Quality Silver Alloy Content Contactors)Gwiec 2 Pole 40 AMP Heavy Duty AC Contactor Replaces Virtually All Residential 2 Pole Models (2- Year Warranty-High Quality Silver Alloy Content Contactors)Gwiec 2 Pole 40 AMP Heavy Duty AC Contactor Replaces Virtually All Residential 2 Pole Models (2- Year Warranty-High Quality Silver Alloy Content Contactors)Gwiec 2 Pole 40 AMP Heavy Duty AC Contactor Replaces Virtually All Residential 2 Pole Models (2- Year Warranty-High Quality Silver Alloy Content Contactors)Gwiec 2 Pole 40 AMP Heavy Duty AC Contactor Replaces Virtually All Residential 2 Pole Models (2- Year Warranty-High Quality Silver Alloy Content Contactors)Gwiec 2 Pole 40 AMP Heavy Duty AC Contactor Replaces Virtually All Residential 2 Pole Models (2- Year Warranty-High Quality Silver Alloy Content Contactors)

Definite Purpose Contactor Feature:

Insulating material Contact block and carrier are high quality electrical-grade thermosetting resin
Temperature range -40°F to 150°F
Mechanical life (no load) Conforms to UL and ARI specifications
Electricl life Conforms to UL and ARI specifications
Weight (approximate) 9.25 oz
Coils Frequency 50/60Hz
Coil insulation Class B (130ºC)
Termination Pressure connector and double 1/4 Q.C
Operate 85%of nominal coil coltage;110% maximum safe operate
Duty cycle Continuous

 

Definite Purpose Contactor Specification:

Model No

Full load

Amps( A )

Resistive Amps(A)

Pole No.

Coil Voltage ( V)

 50/60HZ

Line Voltage (V)

Max HP

 

Voltage (V)

Single Phase

Three Phase

CJX9-20/1

20

30

1

24

240/277

120

1.5

 -

CJX9-20/1.5

1.5

CJX9-20/2

2

CJX9-20/3

3

120

480

240/270

3

7.5

CJX9-20/4

4

208/240

600

480/600

-

7.5

CJX9-25/1.5

25

35

1.5

24

240/277

120

2

-

CJX9-25/2

2

CJX9-25/3

3

120

480

240/270

5

7.5

CJX9-25/4

4

208/240

600

480/600

-

15/20

CJX9-30/1.5

30

40

1.5

24

240/277

120

2

-

CJX9-30/2

2

120

480

240/270

5

10

CJX9-30/3

3

208/240

600

480/600

-

15/20

CJX9-30/4

4

CJX9-40/2

40

50

2

24

240/277

120

3

-

CJX9-40/3

40

50

3

120

480

240/270

7.5

10

CJX9-40/4

40

50

4

208/240

600

480/600

-

15/20

CJX9-50/2

50

60

2

24

240/277

120

3

 

CJX9-50/3

50

60

3

120

480

240/270

10

15

CJX9-50/4

50

60

4

208/240

600

480/600

-

25/25

CJX9-60/2

60

70

2

24

240/277

120

5

-

CJX9-60/3

60

740

3

120

480

240/270

10

20

CJX9-60/4

60

70

4

208/240

600

480/600

-

30/30

CJX9-75/2

75

85

2

24

240/277

120

5

-

CJX9-75/3

75

85

3

120

480

240/270

15

25

CJX9-75/4

75

85

4

208/240

600

480/600

-

40/40

CJX9-90/2

90

100

2

24

240/277

120

7.5

-

CJX9-90/3

90

100

3

120

480

240/270

20

30

CJX9-90/4

90

100

4

208/240

600

480/600

-

50/50

Definite Purpose Contactor Installation:

1.Low VA coil for cooler operation and increased life
2.Quiet operation 
3.Universal style mounting bracket fits existing mounting holes
4. Double break contacts ensure positive make and break
5. Screw terminals or pressure connectors and double 1/4 quick connects provided on all models for easy installation

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory
Registered Capital
10000000 RMB
Plant Area
501~1000 square meters