| Customization: | Available |
|---|---|
| Output Type: | Single |
| Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Type | Technical indicators | ||
| Output | DC voltage | 24V | 48V |
| Rated current | 10A | 5A | |
| Rated power | 240W | 240W | |
| Ripple and noise | <150MV | <150MV | |
| Voltage accuracy | ±1% | ±1% | |
| Voltage regulation range | ±10% | ||
| Load adjustment rate | ±1% | ||
| Linear adjustment rate | ±0.5% | ||
| Input | Voltage range | 85-264VAC 47Hz~63Hz(120VDC~370VDC:By connection AC/L(+),AC/N(-)enables DC input) | |
| Efficiency(typical) | >86% | >90% | |
| Power factor | PF>0.98/115VAC,PF>0.95/230VAC | ||
| Operating current | <2.25A 110VAC <1.3A 220VAC | ||
| Impulse current | 110VAC 20A, 220VAC 35A | ||
| Start up time | 3000ms,100ms,22ms: 100VAC/1500ms,100ms,28ms: 220VAC | ||
| Leakage current | <1mA 240VAC | ||
| Protection characteristics | Overload protection | ≥105%-150% type:protection mode:hiccup mode automatic recovery after abnormal conditions are removed | |
| Overvoltage protection | When the output voltage is greater than 135%,the shutdown output will automatically recover after the abnormal condition is removed | ||
| Short circuit protection | +VO drops to the undervoltage point and the output is closed after the abnormal condition is removed,the power supply restarts and the automatic recovery is resumed | ||
| Over temperature protection | >85ºC turn off the output and recover after the power is restarted after the temperature drops | ||
| Environment | Operating temperature,humidity | -10ºC~+60ºC;20%~+90RH | |
| Storage temperature,humidity | -20ºC~+85ºC;10%~+90RH | ||
| Security | Withstand voltage | Input-output:1.5KVAC input-case:1.5KVAC output-case:0.5KVAC duration:1minute | |
| Isolation resistor | Input-output and input-shell,output-shell:500VDC/100mΩ | ||
| Other | Size | 63*125*113mm(L*W*H) | |
| Net weight/gross weight | 1000g/1100g | ||